See the
      JDBC
      overview for information on JDBC 4.0. Please also check
      the examples/ directory of the download
      package.
    
Notes on using the MySQL Connector/C++ API
          DatabaseMetaData::supportsBatchUpdates()
          returns true because MySQL supports batch
          updates in general. However, no API calls for batch updates
          are provided by the MySQL Connector/C++ API.
        
          Two non-JDBC methods have been introduced for fetching and
          setting unsigned integers: getUInt64() and
          getUInt(). These are available for
          ResultSet and
          Prepared_Statement:
        
              ResultSet::getUInt64()
            
              ResultSet::getUInt()
            
              Prepared_Statement::setUInt64()
            
              Prepared_Statement::setUInt()
            
          The corresponding getLong() and
          setLong() methods have been removed.
        
          The method DatabaseMetaData::getColumns()
          has 23 columns in its result set, rather than the 22 columns
          defined by JDBC. The first 22 columns are as described in the
          JDBC documentation, but column 23 is new:
        
          23. IS_AUTOINCREMENT: String which is
          “YES” if the column is an auto-increment column.
          Otherwise the string contains “NO”.
        
MySQL Connector/C++ may return different metadata for the same column.
When you have any column that accepts a charset and a collation in its specification and you specify a binary collation, such as:
CHAR(250) CHARACTER SET 'latin1' COLLATE 'latin1_bin'
          The server sets the BINARY flag in the
          result set metadata of this column. The method
          ResultSetMetadata::getColumnTypeName() uses
          the metadata and will report, due to the
          BINARY flag, that the column type name is
          BINARY. This is illustrated below:
        
mysql> create table varbin(a varchar(20) character set utf8 collate utf8_bin);
Query OK, 0 rows affected (0.00 sec)
mysql> select * from varbin;
Field   1:  `a`
Catalog:    `def`
Database:   `test`
Table:      `varbin`
Org_table:  `varbin`
Type:       VAR_STRING
Collation:  latin1_swedish_ci (8)
Length:     20
Max_length: 0
Decimals:   0
Flags:      BINARY
0 rows in set (0.00 sec)
mysql> select * from information_schema.columns where table_name='varbin'\G
*************************** 1. row ***************************
           TABLE_CATALOG: NULL
            TABLE_SCHEMA: test
              TABLE_NAME: varbin
             COLUMN_NAME: a
        ORDINAL_POSITION: 1
          COLUMN_DEFAULT: NULL
             IS_NULLABLE: YES
               DATA_TYPE: varchar
CHARACTER_MAXIMUM_LENGTH: 20
  CHARACTER_OCTET_LENGTH: 60
       NUMERIC_PRECISION: NULL
           NUMERIC_SCALE: NULL
      CHARACTER_SET_NAME: utf8
          COLLATION_NAME: utf8_bin
             COLUMN_TYPE: varchar(20)
              COLUMN_KEY:
                   EXTRA:
              PRIVILEGES: select,insert,update,references
          COLUMN_COMMENT:
1 row in set (0.01 sec)
          However, INFORMATION_SCHEMA gives no hint
          in its COLUMNS table that metadata will
          contain the BINARY flag.
          DatabaseMetaData::getColumns() uses
          INFORMATION_SCHEMA. It will report the type
          name CHAR for the same column. Note, a
          different type code is also returned.
        
          The MySQL Connector/C++ class sql::DataType defines
          the following JDBC standard data types:
          UNKNOWN, BIT,
          TINYINT, SMALLINT,
          MEDIUMINT, INTEGER,
          BIGINT, REAL,
          DOUBLE, DECIMAL,
          NUMERIC, CHAR,
          BINARY, VARCHAR,
          VARBINARY, LONGVARCHAR,
          LONGVARBINARY,
          TIMESTAMP, DATE,
          TIME, GEOMETRY,
          ENUM, SET,
          SQLNULL.
        
          However, the following JDBC standard data types are
          not supported by MySQL Connector/C++:
          ARRAY, BLOB,
          CLOB, DISTINCT,
          FLOAT, OTHER,
          REF, STRUCT.
        
          When inserting or updating BLOB or
          TEXT columns, MySQL Connector/C++ developers are advised
          not to use setString(). Instead it is
          recommended that the dedicated API function
          setBlob() be used instead.
        
          The use of setString() can cause a
          Packet
          too large error message. The error will occur if the
          length of the string passed to the connector using
          setString() exceeds
          max_allowed_packet (minus a few bytes
          reserved in the protocol for control purposes). This situation
          is not handled in MySQL Connector/C++, as this could lead to security
          issues, such as extremely large memory allocation requests due
          to malevolently long strings.
        
          However, if setBlob() is used, this problem
          does not arise. This is because setBlob()
          takes a streaming approach based on
          std::istream. When sending the data from
          the stream to MySQL Server, MySQL Connector/C++ will split the stream into
          chunks appropriate for MySQL Server and observe the
          max_allowed_packet setting currently being
          used.
        
            When using setString() it is not possible
            to set max_allowed_packet to a value
            large enough for the string, prior to passing it to MySQL Connector/C++.
            The MySQL 5.1
            documentation
            for max_allowed_packet states: “As
            of MySQL 5.1.31, the session value of this variable is read
            only. Before 5.1.31, setting the session value is allowed
            but has no effect.”
          
This difference with the JDBC specification ensures that MySQL Connector/C++ is not vulnerable to memory flooding attacks.
In general MySQL Connector/C++ works with MySQL 5.0, but it is not completely supported. Some methods may not be available when connecting to MySQL 5.0. This is because the Information Schema is used to obtain the requested information. There are no plans to improve the support for 5.0 because the current GA version of MySQL Server is 5.1. As a new product, MySQL Connector/C++ is primarily targeted at the MySQL Server GA version that was available on its release.
          The following methods will throw a
          sql::MethodNotImplemented exception when
          you connect to MySQL earlier than 5.1.0:
        
              DatabaseMetadata::getCrossReference()
            
              DatabaseMetadata::getExportedKeys()
            
          MySQL Connector/C++ includes a method
          Connection::getClientOption() which is not
          included in the JDBC API specification. The prototype is:
        
void getClientOption(const std::string & optionName, void * optionValue)
          The method can be used to check the value of connection
          properties set when establishing a database connection. The
          values are returned through the optionValue
          argument passed to the method with the type void
          *.
        
          Currently, getClientOption() supports
          fetching the optionValue of the following
          options:
          
                metadataUseInfoSchema
              
                defaultStatementResultType
              
                defaultPreparedStatementResultType
              
          The connection option metadataUseInfoSchema
          controls whether to use the
          Information_Schemata for returning the meta
          data of SHOW commands. In the case of
          metadataUseInfoSchema the
          optionValue argument should be interpreted
          as a boolean upon return.
        
          In the case of both
          defaultStatementResultType and
          defaultPreparedStatementResultType, the
          optionValue argument should be interpreted
          as an integer upon return.
        
          The connection property can be either set when establishing
          the connection through the connection property map or using
          void Connection::setClientOption(const std::string
          & optionName, const void * optionValue) where
          optionName is assigned the value
          metadataUseInfoSchema.
        
Some examples are given below:
int defaultStmtResType;
int defaultPStmtResType;
conn->getClientOption("defaultStatementResultType", (void *) &defaultStmtResType);
conn->getClientOption("defaultPreparedStatementResultType", (void *) &defaultPStmtResType);
bool isInfoSchemaUsed;
conn->getClientOption("metadataUseInfoSchema", (void *) &isInfoSchemaUsed);
MySQL Connector/C++ also supports the following methods not found in the JDBC API standard:
std::string MySQL_Connection::getSessionVariable(const std::string & varname)
void MySQL_Connection::setSessionVariable(const std::string & varname, const std::string & value)
          Note that both methods are members of the
          MySQL_Connection class. The methods get and
          set MySQL session variables.
        
          setSessionVariable() is equivalent to
          executing:
        
SET SESSION <varname> = <value>
          getSessionVariable() is equivalent to
          executing the following and fetching the first return value:
        
SHOW SESSION VARIABLES LIKE "<varname>"
You can use “%” and other placeholders in <varname>, if the underlying MySQL server supports this.
Fetching the value of a column can sometimes return different values depending on whether the call is made from a Statement or Prepared Statement. This is because the protocol used to communicate with the server differs depending on whether a Statement or Prepared Statement is used.
          To illustrate this, consider the case where a column has been
          defined as of type BIGINT. The most
          negative BIGINT value is then inserted into
          the column. If a Statement and Prepared Statement are created
          that perform a GetUInt64() call, then the
          results will be found to be different in each case. The
          Statement returns the maximum positive value for
          BIGINT. The Prepared Statement returns 0.
        
          The reason for the different results is due to the fact that
          Statements use a text protocol, and Prepared Statements use a
          binary protocol. With the binary protocol in this case, a
          binary value is returned from the server that can be
          interpreted as an int64. In the above
          scenario a very large negative value was fetched with
          GetUInt64(), which fetches unsigned
          integers. As the large negative value cannot be sensibly
          converted to an unsigned value 0 is returned.
        
          In the case of the Statement, which uses the text protocol,
          values are returned from the server as strings, and then
          converted as required. When a string value is returned from
          the server in the above scenario the large negative value will
          need to be converted by the runtime library function
          strtoul(), which
          GetUInt64() calls. The behavior of
          strtoul() is dependent upon the specific
          runtime and host operating system, so the results can be
          variable. In the case given a large positive value was
          actually returned.
        
Although it is very rare, there are some cases where Statements and Prepared Statements can return different values unexpectedly, but this usually only happens in extreme cases such as the one mentioned.
          The JDBC documentation
          lists
          many fields for the
          DatabaseMetaData class. JDBC also appears
          to
          define
          certain values for those fields. However, MySQL Connector/C++ does
          not define certain values for those fields. Internally
          enumerations are used and the compiler determines the values
          to assign to a field.
        
To compare a value with the field, code such as the following should be used, rather than making assumptions about specific values for the attribute:
// dbmeta is an instance of DatabaseMetaData
if (myvalue == dbmeta->attributeNoNulls) {
    ...
}
          Usually myvalue will be a column
          from a result set holding metadata information. MySQL Connector/C++ does
          not guarantee that attributeNoNulls is 0.
          It can be any value.
        
          When programming Stored Procedures JDBC has available an extra
          class, an extra abstraction layer for callable statements, the
          CallableStatement class. This is not
          present in MySQL Connector/C++. You therefore need to use the methods from
          the Statement and Prepared
          Statement classes to run a Stored Procedure using
          CALL.
        


User Comments